Leak History 17

The tube leak occurred in a 300MW, Foster Wheeler boiler, equipped with 8 metalborne waveguides and sensors. The sensors on this unit cycle with load.  That is, the signal level increases whenever the load increases, and decreases when load decreases.  On Sunday evening, 10/21 the unit came down in load, but  the signal level for channel 2 remained high.  On Monday morning, as load was increased, channel 2 signaled an alarm.  A short time later channels 4 and 6 also signaled an alarm.

There were no other indications of a leak.  (Read More)

 

 

Number 1 in Acoustic Leak Detection

Triple 5 is a designer and manufacturer of portable, bench top and online acoustic leak detection systems used to find leaks in pressurized vessels including power boilers, recovery boilers and feedwater heaters.


Our Portable and Bench Top equipment can be used to detect:

  • Gas, Air, Steam and Vacuum Leaks

  • Valve Leaks

  • Faulty Steam Traps

  • Worn or Dry Bearings

  • Transformer Defects

  • Tube Leaks Inside Power & Recovery Boilers

  • Feedwater Heater Leaks 

Our 50FD  Fault Detectors are used to find defects in Transformers:

  • Partial Discharge

  • Corona

  • Loose Parts

  • Pump Cavitation

  • Bad Bearings

  • Leaks

Our AMS systems are designed for steam leak detection in:

  • Feedwater Heaters

  • Recovery Boilers

  • Power Boilers

Find the problem before it finds you!

Our On Line Systems, Bench Top and Portable leak detecting equipment will help you locate problem areas in the early stages  before they grow too large causing longer down times, higher repair costs and possible harm to employees.

 